Absorption Cuvette

0 out of 5
(0)
SKU: N/A

For solutions with absorption coefficients that are too high for a standard path length cuvette, we have cuvettes with path lengths 20mm. You can acheive a ten-times reduction in absorbance by simply swapping cuvettes, rather than wasting time and solvent by needing to dilute your solutions.

Read more

Calibration Filter

0 out of 5
(0)
SKU: N/A

LARK calibration filters are an essential accessory for spectrophotometer users. Designed for frequent use, the filter elements are mounted in a standard cuvette sized holder which protects the filter element for damage due to handling.

  • Calibrated using NIST certified standards
  • Optical density and wavelength standards
  • Absorptive filters for visible spectrum
  • Metallic filters for UV-visible spectrum
  • Blank filter holder for dual-beam balance

 

Read more

Circular Dichroism Disc Mount

0 out of 5
(0)
SKU: N/A

Cuvette mount for Circular Dichroism Disc Cells. This mount fastens the two sides of the disc together.

 

Read more

Colorimeter Cell

0 out of 5
(0)
SKU: N/A

Colorimeter cell for CP method. Physical Configuration: Glass cell with wide and tall window. Primary use: Transmission/Absorbtion measurement.

Read more

Cuvette mount for Micro Fluorescence Cuvette with PTFE Cover (Lightpath 5mm)

0 out of 5
(0)
SKU: N/A

Cell Mounts. Cases & Cell Rack … Fluorescence, refractive index, and other optical qualities. Light Path Variable capacity micro/semi-micro cuvette with PTFE cover Spacer for 1mm, 2mm and 5mm lightpath cells.

Read more

Cuvette mount for Micro Fluorescence Cuvette with PTFE Cover (Lightpath: 3mm) and Micro Fluorescence Cuvette with PTFE Stopper (Lightpath: 3mm)

0 out of 5
(0)
SKU: N/A

PTFE cover, side-mounted tubes. Micro, PTFE stopper – 3 x 3 mm lightpath. Absorption or fluorescence measurement

Read more

Cuvette Mounts (For lightpaths below 5mm)

0 out of 5
(0)
SKU: N/A

Cuvette mount for rectangular cells with a lightpath of less than 5mm.
This mount enables short pathlength cuvettes to fit in a 10mm cuvette holder.

Read more

Cuvette spacer (For lightpaths of 1mm, 2mm and 5mm)

0 out of 5
(0)
SKU: N/A

The Cuvette Spacers are made from high quality black anodized aluminum and are designed for allowing you the easy ability to fit smaller lightpath cuvettes of 1, 2 and 5mm into a standard 10mm cuvette holder.

 

Read more

Cuvettes & Cells

0 out of 5
(0)
SKU: N/ARead more

Cylindrical Cell

0 out of 5
(0)
SKU: N/A

A cylindrical cell consists of sheet-like anodes, separators, and cathodes that are sandwiched, rolled up, and packed into a cylinder-shaped can. This type is one of the first mass-produced types of batteries and is still very popular.

Read more

Cylindrical Cell with quartz-to-pyrex graded seal tube (Lightpaths: 1-100mm)

0 out of 5
(0)
SKU: N/A

Cuvette with a cylindrical chamber for polarimetric applications and a quartz-to-pyrex graded seal tube for adding additional structures to the top portion of the cell.

Read more

Demountable U-Shaped Circular Dichroism Cuvette (Lightpaths: 0.05-2mm)

0 out of 5
(0)
SKU: N/A

LARK demountable flow through cell with sides tubes enables a constant flow through the observation chamber. The demountable slides enables a user to insert a small sample and reassemble the cuvette. These are popular among researchers who perform CD (Circular Dichroism) experiments.

Read more

Electrophoresis Flow Through Cell (Lightpath: 2mm)

0 out of 5
(0)
SKU: N/A

Flow through cell for use in electrophoresis.

 

Read more

Flow Through Cell with Side Tubes (Lightpaths: 0.05-10mm)

0 out of 5
(0)
SKU: N/A

LARK flow through cell with sides tubes enables a constant flow through the observation chamber.

Read more

Fluorometer Cell

0 out of 5
(0)
SKU: N/A

A fluorometer or fluorimeter is a device used to measure parameters of visible spectrum.

Read more

FTIR cylindrical & universal cuvette holder

0 out of 5
(0)
SKU: N/A

Universal 50mm FTIR cylindrical cuvette holder for use with UV/VIS and Infrared spectrophotometers

Read more

FTIR rectangular cuvette holder

0 out of 5
(0)
SKU: N/A

Cuvette holders for IR and FTIR instruments. Has a 3 inch x 2 inch back plate.

Read more

Gas Absorption Cell with quartz-to-glass Graded Seal Tube (Lightpath:74mm)

0 out of 5
(0)
SKU: N/A

Gas absorption cuvette with quartz-to-glass graded seal tube, UV quartz, lightpath 74 mm. Available materials: UV quartz, IR quartz;

  • Available materials: UV quartz, IR quartz
  • Available lightpath: 74mm
  • Two windows optically polished
  • Overall height approx. 84mm
Read more

IR Windows for FTIR Spectroscopy and Other Application Areas

0 out of 5
(0)
SKU: N/ARead more
6800 7500

LARK LCSA-4 Series: Cuvette Adapter Mounts (For Lightpaths Below 5mm)

0 out of 5
(0)
SKU: LCSA-4

Various holders, spacers, and Cuvette Adapter Mounts enable you to fit cuvettes with odd dimensions into a standard spectrophotometer holder. Cuvette mount for short path length cuvette 1 – 5 mm. This cuvette adapter enables short path length cuvettes to fit in a 10mm cuvette holder.

Add to cart

Absorption Cuvette

0 out of 5
(0)

For solutions with absorption coefficients that are too high for a standard path length cuvette, we have cuvettes with path lengths 20mm. You can acheive a ten-times reduction in absorbance by simply swapping cuvettes, rather than wasting time and solvent by needing to dilute your solutions.

SKU: N/A

Calibration Filter

0 out of 5
(0)

LARK calibration filters are an essential accessory for spectrophotometer users. Designed for frequent use, the filter elements are mounted in a standard cuvette sized holder which protects the filter element for damage due to handling.

  • Calibrated using NIST certified standards
  • Optical density and wavelength standards
  • Absorptive filters for visible spectrum
  • Metallic filters for UV-visible spectrum
  • Blank filter holder for dual-beam balance

 

SKU: N/A

Circular Dichroism Disc Mount

0 out of 5
(0)

Cuvette mount for Circular Dichroism Disc Cells. This mount fastens the two sides of the disc together.

 

SKU: N/A

Colorimeter Cell

0 out of 5
(0)

Colorimeter cell for CP method. Physical Configuration: Glass cell with wide and tall window. Primary use: Transmission/Absorbtion measurement.

SKU: N/A

Cuvette mount for Micro Fluorescence Cuvette with PTFE Cover (Lightpath 5mm)

0 out of 5
(0)

Cell Mounts. Cases & Cell Rack … Fluorescence, refractive index, and other optical qualities. Light Path Variable capacity micro/semi-micro cuvette with PTFE cover Spacer for 1mm, 2mm and 5mm lightpath cells.

SKU: N/A

Cuvette mount for Micro Fluorescence Cuvette with PTFE Cover (Lightpath: 3mm) and Micro Fluorescence Cuvette with PTFE Stopper (Lightpath: 3mm)

0 out of 5
(0)

PTFE cover, side-mounted tubes. Micro, PTFE stopper – 3 x 3 mm lightpath. Absorption or fluorescence measurement

SKU: N/A

Cuvette Mounts (For lightpaths below 5mm)

0 out of 5
(0)

Cuvette mount for rectangular cells with a lightpath of less than 5mm.
This mount enables short pathlength cuvettes to fit in a 10mm cuvette holder.

SKU: N/A

Cuvette spacer (For lightpaths of 1mm, 2mm and 5mm)

0 out of 5
(0)

The Cuvette Spacers are made from high quality black anodized aluminum and are designed for allowing you the easy ability to fit smaller lightpath cuvettes of 1, 2 and 5mm into a standard 10mm cuvette holder.

 

SKU: N/A

Cylindrical Cell

0 out of 5
(0)

A cylindrical cell consists of sheet-like anodes, separators, and cathodes that are sandwiched, rolled up, and packed into a cylinder-shaped can. This type is one of the first mass-produced types of batteries and is still very popular.

SKU: N/A

Cylindrical Cell with quartz-to-pyrex graded seal tube (Lightpaths: 1-100mm)

0 out of 5
(0)

Cuvette with a cylindrical chamber for polarimetric applications and a quartz-to-pyrex graded seal tube for adding additional structures to the top portion of the cell.

SKU: N/A

Demountable U-Shaped Circular Dichroism Cuvette (Lightpaths: 0.05-2mm)

0 out of 5
(0)

LARK demountable flow through cell with sides tubes enables a constant flow through the observation chamber. The demountable slides enables a user to insert a small sample and reassemble the cuvette. These are popular among researchers who perform CD (Circular Dichroism) experiments.

SKU: N/A

Flow Through Cell with Side Tubes (Lightpaths: 0.05-10mm)

0 out of 5
(0)

LARK flow through cell with sides tubes enables a constant flow through the observation chamber.

SKU: N/A

Fluorometer Cell

0 out of 5
(0)

A fluorometer or fluorimeter is a device used to measure parameters of visible spectrum.

SKU: N/A
Availability:

Out of stock

Read more

FTIR cylindrical & universal cuvette holder

0 out of 5
(0)

Universal 50mm FTIR cylindrical cuvette holder for use with UV/VIS and Infrared spectrophotometers

SKU: N/A

FTIR rectangular cuvette holder

0 out of 5
(0)

Cuvette holders for IR and FTIR instruments. Has a 3 inch x 2 inch back plate.

SKU: N/A

Gas Absorption Cell with quartz-to-glass Graded Seal Tube (Lightpath:74mm)

0 out of 5
(0)

Gas absorption cuvette with quartz-to-glass graded seal tube, UV quartz, lightpath 74 mm. Available materials: UV quartz, IR quartz;

  • Available materials: UV quartz, IR quartz
  • Available lightpath: 74mm
  • Two windows optically polished
  • Overall height approx. 84mm
SKU: N/A

LARK LCSA-4 Series: Cuvette Adapter Mounts (For Lightpaths Below 5mm)

0 out of 5
(0)

Various holders, spacers, and Cuvette Adapter Mounts enable you to fit cuvettes with odd dimensions into a standard spectrophotometer holder. Cuvette mount for short path length cuvette 1 – 5 mm. This cuvette adapter enables short path length cuvettes to fit in a 10mm cuvette holder.

SKU: LCSA-4
Availability:

5 in stock

6800 7500 Add to cart

Absorption Cuvette

0 out of 5
(0)

For solutions with absorption coefficients that are too high for a standard path length cuvette, we have cuvettes with path lengths 20mm. You can acheive a ten-times reduction in absorbance by simply swapping cuvettes, rather than wasting time and solvent by needing to dilute your solutions.

Calibration Filter

0 out of 5
(0)

LARK calibration filters are an essential accessory for spectrophotometer users. Designed for frequent use, the filter elements are mounted in a standard cuvette sized holder which protects the filter element for damage due to handling.

  • Calibrated using NIST certified standards
  • Optical density and wavelength standards
  • Absorptive filters for visible spectrum
  • Metallic filters for UV-visible spectrum
  • Blank filter holder for dual-beam balance

 

Circular Dichroism Disc Mount

0 out of 5
(0)

Cuvette mount for Circular Dichroism Disc Cells. This mount fastens the two sides of the disc together.

 

Colorimeter Cell

0 out of 5
(0)

Colorimeter cell for CP method. Physical Configuration: Glass cell with wide and tall window. Primary use: Transmission/Absorbtion measurement.

Cuvette mount for Micro Fluorescence Cuvette with PTFE Cover (Lightpath 5mm)

0 out of 5
(0)

Cell Mounts. Cases & Cell Rack … Fluorescence, refractive index, and other optical qualities. Light Path Variable capacity micro/semi-micro cuvette with PTFE cover Spacer for 1mm, 2mm and 5mm lightpath cells.

Cuvette Mounts (For lightpaths below 5mm)

0 out of 5
(0)

Cuvette mount for rectangular cells with a lightpath of less than 5mm.
This mount enables short pathlength cuvettes to fit in a 10mm cuvette holder.

Cuvette spacer (For lightpaths of 1mm, 2mm and 5mm)

0 out of 5
(0)

The Cuvette Spacers are made from high quality black anodized aluminum and are designed for allowing you the easy ability to fit smaller lightpath cuvettes of 1, 2 and 5mm into a standard 10mm cuvette holder.

 

Cylindrical Cell

0 out of 5
(0)

A cylindrical cell consists of sheet-like anodes, separators, and cathodes that are sandwiched, rolled up, and packed into a cylinder-shaped can. This type is one of the first mass-produced types of batteries and is still very popular.

Cylindrical Cell with quartz-to-pyrex graded seal tube (Lightpaths: 1-100mm)

0 out of 5
(0)

Cuvette with a cylindrical chamber for polarimetric applications and a quartz-to-pyrex graded seal tube for adding additional structures to the top portion of the cell.

Demountable U-Shaped Circular Dichroism Cuvette (Lightpaths: 0.05-2mm)

0 out of 5
(0)

LARK demountable flow through cell with sides tubes enables a constant flow through the observation chamber. The demountable slides enables a user to insert a small sample and reassemble the cuvette. These are popular among researchers who perform CD (Circular Dichroism) experiments.

Flow Through Cell with Side Tubes (Lightpaths: 0.05-10mm)

0 out of 5
(0)

LARK flow through cell with sides tubes enables a constant flow through the observation chamber.

Fluorometer Cell

0 out of 5
(0)

A fluorometer or fluorimeter is a device used to measure parameters of visible spectrum.

Availability:

Out of stock

Read more

FTIR cylindrical & universal cuvette holder

0 out of 5
(0)

Universal 50mm FTIR cylindrical cuvette holder for use with UV/VIS and Infrared spectrophotometers

Gas Absorption Cell with quartz-to-glass Graded Seal Tube (Lightpath:74mm)

0 out of 5
(0)

Gas absorption cuvette with quartz-to-glass graded seal tube, UV quartz, lightpath 74 mm. Available materials: UV quartz, IR quartz;

  • Available materials: UV quartz, IR quartz
  • Available lightpath: 74mm
  • Two windows optically polished
  • Overall height approx. 84mm

LARK LCSA-4 Series: Cuvette Adapter Mounts (For Lightpaths Below 5mm)

0 out of 5
(0)

Various holders, spacers, and Cuvette Adapter Mounts enable you to fit cuvettes with odd dimensions into a standard spectrophotometer holder. Cuvette mount for short path length cuvette 1 – 5 mm. This cuvette adapter enables short path length cuvettes to fit in a 10mm cuvette holder.

Availability:

5 in stock

6800 7500 Add to cart

Absorption Cuvette

0 out of 5
(0)

For solutions with absorption coefficients that are too high for a standard path length cuvette, we have cuvettes with path lengths 20mm. You can acheive a ten-times reduction in absorbance by simply swapping cuvettes, rather than wasting time and solvent by needing to dilute your solutions.

Calibration Filter

0 out of 5
(0)

LARK calibration filters are an essential accessory for spectrophotometer users. Designed for frequent use, the filter elements are mounted in a standard cuvette sized holder which protects the filter element for damage due to handling.

  • Calibrated using NIST certified standards
  • Optical density and wavelength standards
  • Absorptive filters for visible spectrum
  • Metallic filters for UV-visible spectrum
  • Blank filter holder for dual-beam balance

 

Circular Dichroism Disc Mount

0 out of 5
(0)

Cuvette mount for Circular Dichroism Disc Cells. This mount fastens the two sides of the disc together.

 

Colorimeter Cell

0 out of 5
(0)

Colorimeter cell for CP method. Physical Configuration: Glass cell with wide and tall window. Primary use: Transmission/Absorbtion measurement.

Cuvette mount for Micro Fluorescence Cuvette with PTFE Cover (Lightpath 5mm)

0 out of 5
(0)

Cell Mounts. Cases & Cell Rack … Fluorescence, refractive index, and other optical qualities. Light Path Variable capacity micro/semi-micro cuvette with PTFE cover Spacer for 1mm, 2mm and 5mm lightpath cells.

Cuvette Mounts (For lightpaths below 5mm)

0 out of 5
(0)

Cuvette mount for rectangular cells with a lightpath of less than 5mm.
This mount enables short pathlength cuvettes to fit in a 10mm cuvette holder.

Cuvette spacer (For lightpaths of 1mm, 2mm and 5mm)

0 out of 5
(0)

The Cuvette Spacers are made from high quality black anodized aluminum and are designed for allowing you the easy ability to fit smaller lightpath cuvettes of 1, 2 and 5mm into a standard 10mm cuvette holder.

 

Cylindrical Cell

0 out of 5
(0)

A cylindrical cell consists of sheet-like anodes, separators, and cathodes that are sandwiched, rolled up, and packed into a cylinder-shaped can. This type is one of the first mass-produced types of batteries and is still very popular.

Cylindrical Cell with quartz-to-pyrex graded seal tube (Lightpaths: 1-100mm)

0 out of 5
(0)

Cuvette with a cylindrical chamber for polarimetric applications and a quartz-to-pyrex graded seal tube for adding additional structures to the top portion of the cell.

Demountable U-Shaped Circular Dichroism Cuvette (Lightpaths: 0.05-2mm)

0 out of 5
(0)

LARK demountable flow through cell with sides tubes enables a constant flow through the observation chamber. The demountable slides enables a user to insert a small sample and reassemble the cuvette. These are popular among researchers who perform CD (Circular Dichroism) experiments.

Flow Through Cell with Side Tubes (Lightpaths: 0.05-10mm)

0 out of 5
(0)

LARK flow through cell with sides tubes enables a constant flow through the observation chamber.

Fluorometer Cell

0 out of 5
(0)

A fluorometer or fluorimeter is a device used to measure parameters of visible spectrum.

FTIR cylindrical & universal cuvette holder

0 out of 5
(0)

Universal 50mm FTIR cylindrical cuvette holder for use with UV/VIS and Infrared spectrophotometers

Gas Absorption Cell with quartz-to-glass Graded Seal Tube (Lightpath:74mm)

0 out of 5
(0)

Gas absorption cuvette with quartz-to-glass graded seal tube, UV quartz, lightpath 74 mm. Available materials: UV quartz, IR quartz;

  • Available materials: UV quartz, IR quartz
  • Available lightpath: 74mm
  • Two windows optically polished
  • Overall height approx. 84mm

LARK LCSA-4 Series: Cuvette Adapter Mounts (For Lightpaths Below 5mm)

0 out of 5
(0)

Various holders, spacers, and Cuvette Adapter Mounts enable you to fit cuvettes with odd dimensions into a standard spectrophotometer holder. Cuvette mount for short path length cuvette 1 – 5 mm. This cuvette adapter enables short path length cuvettes to fit in a 10mm cuvette holder.

6800 7500 Add to cart